• Active Ice Management: Engineered to maintain open drainage pathways at flat roof drains and scuppers, preventing water backup and standing water during heavy snow and ice conditions.
  • 6-Point Distribution: Features a specialized 6-arm support system that precisely routes and protects the heating cable to ensure maximum heat coverage around the drain perimeter.
  • High-Efficiency Heating: Includes a 50 ft, 120V heating cable rated at 5W per foot, providing consistent thermal performance to melt through blockages and keep water flowing.
  • Mechanical Attachment: Designed for a secure, adhesive-free installation using existing drain bolts, allowing for easier maintenance access and long-term durability on commercial rooftops.
Best Price Guaranteed
Price: $879.45
    Item #HTS-RDHS-6
    Write a review!

    Description

    The Heat Trace Specialists RDHS-6 Flat Roof Drain Heater System is designed to help keep drainage paths open on flat roofs during snow and ice conditions. It uses a 6-point arm system to support and route heating cable around roof drains and scuppers where buildup typically blocks water flow.

    The system includes a 50 ft heated cable and installs directly to the drain without adhesive. It is used to reduce standing water and backup issues by maintaining a clear path for drainage in cold weather.

    Key Features

    • Helps open drainage pathways at roof drains and scuppers
    • 6-point arm design supports and protects heating cable
    • Includes 50 ft heated cable (120V, 5W)
    • Installs without adhesive for easier access and maintenance
    • Designed for use in snow and ice conditions on flat roofs
    • Simple installation with adjustable arm positioning

    Specifications

    Type: Roof Drain Heater System (RDHS)

    Configuration: 6-point system

    Application: Flat roof drains and scuppers

    Included Cable: 50 ft heating cable

    Voltage: 120V

    Wattage: 5W cable

    Installation: Mechanical attachment (no adhesive required)

    How To

    • Prepare the drain area and remove the drain dome as needed, protecting the drain opening.
    • Install the base hardware and clamping collar using the existing drain bolts.
    • Adjust the assembly height to align properly with the roof surface.
    • Install and position the 6-point arms, trimming only if required to clear obstructions.
    • Route and secure the heating cable through the system and into the drain per the installation guide.

    FAQs

    Q: What does the RDHS-6 system do? 
    A:
    It helps open drainage pathways to flat roof drains and scuppers when snow and ice block normal water flow.

    Q: What is included with this system?
    A:
    The RDHS-6 system includes a 50 ft heating cable rated at 5 Watt, 120 Volt.

    Q: Does this system require adhesive for installation?
    A:
    No. The RDHS-6 system is designed to install without adhesive.

    Q: Is installation guidance available?
    A:
    Yes. An installation and routing guide is provided to show proper assembly and cable placement.

    Reviews (0) • Write a review!

    This product has no reviews yet. Write a review!

    Related Items
    AP 3550 - 10” Thermostat Extension Cable Ambient...
    Designed to automatically activate heat trace systems when the ambient temperature drops to 35°F and turn them off at 50°F.
    Price: $170.00
    Availability: In Stock
    Usually ships within 1-2 Business Days

      The AP 3550 - 10” Thermostat Extension Cable is a plug-in temperature control used with heat trace systems. It automatically turns power on when temperatures drop to 35°F and shuts off at 50°F to help prevent freezing. This thermostat installs inline between the power source and heat cable with no setup required. It is used on roof and gutter systems, pipes, and other applications where automatic temperature-based operation is needed. Key Features Automatically turns on at 35°F and off at...